horizontal fan coil unit including horizontal concealed fan coil unit and Horizontal Surface Mounted Fan Coil Unit
Optional remote control
Fp-hc horizontal concealed fan coil unit (bellows, rear return air outlet, lower return air outlet)
Outlet
condensate outlet
rear return air outlet
Water inlet
lower return air outlet
Size of Fp-hc horizontal concealed fan coil unit
model size |
34 | 51 | 68 | 85 | 105 | 136 | 170 | 204 | 238 |
Total length(A) | 740 | 840 | 940 | 1040 | 1140 | 1440 | 1640 | 1840 | 1940 |
hole for hoist (B) | 520 | 620 | 740 | 840 | 940 | 1190 | 1390 | 1540 | 1740 |
Air Outlet (C) | 480 | 580 | 700 | 800 | 900 | 1150 | 1350 | 1500 | 1700 |
return air inlet (D) | 500 | 600 | 720 | 820 | 920 | 1170 | 1370 | 1520 | 1720 |
weight Kg | 12 | 14 | 16 | 18 | 20 | 25 | 29 | 32 | 35 |
Weight with return bellows kg | 15 | 17 | 20 | 22 | 23 | 30 | 34.5 | 38 | 42 |
Model
Size |
34 | 51 | 68 | 85 | 102 | 136 | 170 |
Total length(A) | 840 | 940 | 1040 | 1140 | 1240 | 1440 | 1640 |
hole for hoist (B) | 570 | 670 | 790 | 890 | 990 | 1240 | 1440 |
Air Outlet (C) | 530 | 630 | 750 | 850 | 950 | 1200 | 1400 |
return air inlet (D) | 550 | 650 | 770 | 870 | 975 | 1220 | 1420 |
Model
Size |
51 | 68 | 85 | 102 | 136 |
Total length(A) | 840 | 940 | 1040 | 1140 | 1440 |
hole for hoist (B) | 610 | 730 | 830 | 930 | 1180 |
Air Outlet (C) | 580*80 | 700*80 | 800*80 | 900*80 | 1150*80 |
return air inlet (D) | 580*120 | 700*120 | 800*120 | 900*120 | 1150*120 |
Dimensions | 840*450*160 | 940*450*160 | 1040*450*160 | 1140*450*160 | 1440*450*160 |
Note:
Model
Size |
34 | 51 | 68 | 85 | 102 | 136 | 170 | 204 | 238 |
A | 830 | 930 | 1050 | 1150 | 1250 | 1550 | 1700 | 1850 | 2050 |
B | 480 | 580 | 700 | 800 | 900 | 1150 | 1350 | 1500 | 1700 |
weighgt Kg | 39 | 45.5 | 51 | 60 | 66 | 70 | 77 | 85 | 92 |
Overview
The FP series fan-coil air conditioner is mainly composed of a fan, a motor, a heat exchanger (coil), a condensate tray, a shell, and a controller. It is suitable for centralized air-conditioning systems. Due to the low noise and flexible temperature adjustment characteristics of the fan coil produced by our company, it is widely used in hotels, guesthouses, apartments, restaurants, hospitals, commercial office buildings, and other places.
Model meaning and description
Note:
For example FC51-HC -R
Water inlet method code
Left style: L
Right style: R
Model code:
Horizontal concealed installation: HC
Horizontal opening installation: HO
Vertical concealed installation: VC
Vertical opening installation: VO
Wall-mounted: WM
Column type: CT
Nominal air volume: 10 times the specification figure
Product code: Indicates fan coil
Note:
The distinction between left and right styles: When looking at the air outlet of the fan coil, the lleft-hand side of the piping is the left style, and vice versa when it is the right style.
The core advantage of the product
Main parameters of fan coil air conditioner
Model comparison | British model | FC200 | FC300 | FC400 | FC500 | FC600 | FC800 | FC1000 | FC1200 | FC1400 | ||||||||
standard modle | FP-3.5 | FP-5.0 | FC- 6.3
7.1 |
FP-8 | FP-10 | FP-12.5
14 |
FP-16 | FP-20 | PF-25 | |||||||||
Gb model | FP-34 | FP-51 | FP-65 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 | |||||||||
Air volume
M3/H |
High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | ||||||||
Middle | 255 | 383 | 510 | 638 | 765 | 1020 | 1275 | 1530 | 1785 | |||||||||
low | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | 1190 | |||||||||
Cooling capacity
W |
High | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12800 | ||||||||
Middle | 1620 | 2440 | 3290 | 4120 | 4850 | 6550 | 8190 | 9730 | 11580 | |||||||||
low | 1310 | 2010 | 2650 | 3320 | 3900 | 5300 | 6610 | 7860 | 9350 | |||||||||
Heat supply
W |
High | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | ||||||||
Middle | 2350 | 3520 | 4530 | 6040 | 6850 | 9260 | 11750 | 14140 | 16360 | |||||||||
low | 1620 | 2470 | 3130 | 4170 | 4740 | 6500 | 8180 | 9710 | 11290 | |||||||||
Cold water supply temperature | 7℃-12℃ | |||||||||||||||||
Hot water supply temperature | 60℃ | |||||||||||||||||
power supply | AC110-220V/50HZ | |||||||||||||||||
heat exchanger | type | Copper tube string aluminum sheet, sheet pitch 2.2mm | ||||||||||||||||
Three-row water supply KG/H | 324 | 482 | 655 | 814 | 936 | 1276 | 1602 | 1915 | 2178 | |||||||||
Water resistance KPa | 30 | 30 | 30 | 30 | 40 | 40 | 40 | 40 | 50 | |||||||||
Operating pressure | 1.6MPa | |||||||||||||||||
Low static pressure unit | input power W | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | ||||||||
Motor Power W | 8 | 12 | 18 | 22 | 32 | 20×2 | 25×2 | 35×2 | 42×2 | |||||||||
High static pressure
unit |
Static pressure 30Pa | input power W | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 | |||||||
Motor Power W | 40 | 18 | 22 | 30 | 40 | 25×2 | 35×2 | 42×2 | 60×2 | |||||||||
Static pressure 50Pa | input power W | 49 | 66 | 84 | 100 | 118 | 174 | 210 | 250 | 300 | ||||||||
Motor Power W | 16 | 22 | 30 | 40 | 50 | 35×2 | 42×2 | 60×2 | 75×2 | |||||||||
Number of fans | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | |||||||||
Noise dB(A) | Low static pressure unit | ≤37 | ≤39 | ≤41 | ≤43 | ≤45 | ≤46 | ≤48 | ≤50 | ≤52 | ||||||||
High static pressure 30Pa | ≤40 | ≤42 | ≤44 | ≤46 | ≤47 | ≤48 | ≤50 | ≤52 | ≤54 | |||||||||
High static pressure 50Pa | ≤42 | ≤44 | ≤46 | ≤47 | ≤49 | ≤50 | ≤52 | ≤54 | ≤56 | |||||||||
Specification of connecting pipe | Inlet and outlet pipes | ZG3/4 internal three condensate | ||||||||||||||||
Condensate pipe | ZG3/4 External thread | |||||||||||||||||
We will contact you within 1 working day.