Combined air conditioning unit

Product details

A combined air conditioning unit is one of the most important air treatment equipment, it is without cold and heat source. It is based on hot and cold water or steam as the medium, complete the air filtration, purification, heating, cooling, humidification, dehumidification, clear sound, fresh air treatment, and other functions. It is a box unit.

Fresh air into the air conditioning unit, with indoor return air mixture in the mixing section, after coarse efficiency filter air mixture, removal of dust and debris, and then after effect tachycardia in the period of the secondary filter, filter the smaller dust and debris, and then, through the cold or heat section in the table after cooling or heating air is made to reach the required temperature, Then humidify to the humidity required by the system through the humidification section, that is, reach the specified air supply state point, and finally, send the processed air into the room through the fan section.

Combined air conditioning function section: mixing section, middle effect, secondary return air section, surface cooling section, heating section, humidification section, muffler section, equalizing flow section, fan section, etc.

Example: BFP to 40

Pressure: 200-260 pa

Cold capacity: 22.4 to 59.3 kW

Heat capacity: 38.1 to 64.33 kW

Water volume: 3.9-10.2 (T/h)

Water resistance: 4.6 to 12.4 kpa

Power: 0.75 kw

Noise: 58 dB

Weight: 195-255kg (for reference only)

 

01 Detail Design

Adopt frame and plate structure, no cold bridge design, water pan integral stamping molding.  Internal oxidation treatment, the whole water pan stamping molding.

 

02 Process performance

Beautiful appearance design, product process continuous improvement, improve quality acceptance standards.

 

03 Wide applicability

A: Theaters, high-end hotels, high-end office buildings, and other places.

B: Supporting products of all kinds of central air-conditioning units, HVAC, purification, and ventilation equipment.

 

04 Delivery Inspection

All products are tested before leaving the factory.

Technical energy table of BFP VAV air conditioning unit

performance

model

Air Volume (m3/h) Residual Pressure(Pa) Cold capacity(KW) Heat capacity(KW) Water volume(T/h) Water resistance(Kpa) Power:(KW) Noise dB(A) weight(Kg)
Return air condition Fresh air condition Return air condition Fresh air condition Return air condition Fresh air condition Return air condition Fresh air condition
BFP-20W/L 2000 200 11.2 22.5 19.1 28.00 1.9 3.9 3.5 4.2 0.32 55 140/160
BFP-20XW/L 160 13.9 29.7 25.7 32.67 2.4 5.1 4.5 5.6 160/190
BFP-30W/L 3000 260 16.8 33.8 28.6 42.00 2.9 5.8 4.5 6.4 0.55 56 160/180
BFP-30XW/L 220 20.8 44.5 38.5 49.00 3.6 7.7 5.3 8.5 180/210
BFP-40W/L 4000 260 22.4 45.1 38.1 56.0 3.9 7.7 4.6 6.7 0.75 58 195/220
BFP-40XW/L 200 27.7 59.3 51.3 64.33 4.8 10.2 4.6 6.7 225/255
BFP-45W/L 4500 260 25.2 50.7 42.9 63.00 4.3 8.7 5.2 8.6 0.75 58 205/220
BFP-45XW/L 200 31.2 66.8 57.8 73.50 5.4 11.5 7.4 15.4 215/235
BFP-50W/L 5000 300 28.0 56.3 47.7 70.00 4.8 9.7 6.8 10.7 1.1 59 220/235
BFP-50XW/L 260 34.7 74.2 64.2 81.67 6.0 12.8 8.1 19.5 230/255
BFP-55W/L 5500 300 30.8 62.0 52.4 77.00 5.3 10.7 6.5 12.7 1.5 59 238/256
BFP-55XW/L 260 38.1 81.6 70.6 89.83 6.6 14.0 9.5 20.3 256/286
BFP-60W/L 6000 300 33.6 67.6 57.2 84.00 5.8 11.6 7.4 14.8 1.5 60 256/285
BFP-60XW/L 260 41.6 89.0 77.0 98;0 7.2 15.3 11.3 28.2 285/312
BFP-70W/L 7000 300 39.2 78.9 66.7 98.00 6.7 13.6 8.5 16.5 1.8 61 282/312
BFP-70XW/L 260 48.5 103.8 89.8 114.33 8.3 17.9 14.6 33.3 315/346
BFP-80W/L 8000 360 44.8 90.1 76.3 112.00 7.7 15.5 9.06 18.4 2.2 62 310/345
BFP-80XW/L 300 55.5 118.7 102.7 130.67 9.5 20.4 16.4 39.6 338/369
BFP-90W/L 9000 360 50.4 101.4 85.8 126.00 8.7 17.4 10.6 22.4 2.2 63 322/358
BFP-90XW/L 300 62.4 133.5 115.5 147.00 10.7 23.0 18.2 43.6 345/369
BFP-100W/L 10000 400 56.0 112.7 95.3 140.00 9.6 19.4 12.4 26.7 3.0 64 336/368
BFP-100XW/L 360 69.3 148.3 128.3 163.33 11.9 25.5 21.6 48.6 356/389
BFP-120W/L 12000 450 67.2 135.2 114.4 168.00 11.6 23.2 18.7 40.1 1.8*2 64 438/475
BFP-120XW/L 400 83.2 178.0 154.0 196.00 14.3 30.6 28.4 53.2 476/506
BFP-150W/L 15000 450 84.0 169 143.0 210.00 12.4 29.1 22.6 42.6 2.2*2 64 520/550
BFP-150XW/L 400 104.0 222.5 192.5 245.00 17.9 38.3 35.7 73.5 562/598
BFP-180W/L 18000 450 100.8 202.8 171.6 252.00 17.3 34.9 25.1 44.2 3.0*2 65 556/581
BFP-180XW/L 400 124.8 267.0 231.0 294.00 21.5 45.9 47.7 78.2 585/615
BFP-200W/L 20000 450 112.0 225.3 190.7 280.00 19.3 38.7 28.7 46.5 3.0*3 65 576/595
BFP-200XW/L 400 138.7 296.7 256.7 326.67 23.8 51.6 82.6 610/638
BFP-230W/L 23000 500 128.8 259.1 219.3 322.00 22.1 44.6 29.7 48.7 4.0*2 68 612/635
BFP-230XW/L 450 159.5 342.1 295.2 375.67 27.4 58.7 51.6 85.2 639/672
BFP-250W/L 25000 500 140.0 281.7 238.3 350.00 24.1 48.4 26.5 49.6 4.0*2 69 652/686
BFP-250XW/L 450 173.3 370.8 320.8 408.33 29.8 63.8 50.2 82.6 710/732
BFP-280W/L 28000 550 156.8 315.5 266.9 392.00 27.0 54.2 32.6 43.6 5.5*2 70 679/712
BFP-280XW/L 500 194.1 415.3 359.3 457.33 33.4 71.4 54.5 92.5 729/758
BFP-300W/L 30000 550 168.0 338.0 286.0 420.00 28.9 58.1 36.9 52.3 5.5*2 70 712/735
BFP-300XW/L 500 208.0 445.0 385.0 490.00 35.8 76.5 57.2 91.2 765/796
BFP-350W/L 35000 600 196.0 394.3 333.7 490.00 33.7 67.8 38.7 59.4 7.5*2 72 826/998
BFP-350XW/L 550 242.7 519.2 449.2 571.67 41.7 89.3 58.7 96.2 910/1110

Note: 1. Return air condition: air drying bulb temperature 27℃, wet bulb temperature 19.5℃, water inlet temperature 7℃, water inlet temperature 5℃.

Air drying bulb temperature for heating 15℃, hot water inlet temperature 60℃

2, fresh air condition: cooling inlet air-drying bulb temperature 34℃, wet bulb temperature 28℃, water inlet temperature 7C, inlet water temperature difference 5℃.  Air drying bulb temperature of heating -4℃, hot water inlet temperature of 60℃